Analysis of 3-MCPD, 2-MCPD and GE in free and esterified form

Author: Boris Bučar, mag. ing.
Date: July 3, 2023
Tag: TECHNOLOGY
hero image

3-Monochloropropane-1,2-diol (3-MCPD), 2-Monochloropropane-1,3-diol (2-MCPD) and glycidyl esters (GE) are contaminants that can arise during food production and can end up in food products and pose a potential risk to human health. They are most often found in products that have undergone refining, deodorization, frying or fermentation processes such as:

  • herbal oils

  • margarines and fats

  • bread and pastries

  • fine bakery products

  • smoked fish products

  • delicatessen

  • breaded and roasted meat

  • potato-based snacks and potato-based fried products

  • cereal-based snacks

  • spices and

  • protein hydrolysates.

In order to ensure the safety of the mentioned products, it is important to carry out the analysis and quantification of the presence of these compounds in free and esterified form.

3-MCPD (3-monochloropropane-1,2-diol) is classified as a possible human carcinogen, and in 2013 EFSA's Scientific Committee for Food established a permissible daily intake (TDI) of 0.8 μg/kg body weight .

The analysis of 3-MCPD, 2-MCPD and GE is carried out using different methods, and one of the recognized methods is gas chromatography with a mass spectrometer (GC-MS). This technique enables the separation and identification of compounds based on their chemical properties and mass fragments.

To be analyzed, food samples must first be prepared. Depending on the form of the analyte (free or esterified form), samples are subjected to transesterification and derivatization.

After sample preparation, analysis is performed on a GC-MS device. The prepared samples are injected into a gas chromatograph, which separates the compounds based on their chemical properties with a suitable analytical column. The compounds are then detected and quantified using a mass spectrometer that generates mass fragments and enables identification of the compounds. To increase the precision and reliability of the results, internal standards are used.

It is important to note that Commission Regulation (EU) 2023/915 establishes maximum permitted levels of these contaminants in food products in order to protect consumer safety and to limit the presence of 3-MCPD, 2-MCPD and GE in food.

Analysis of 3-MCPD, 2-MCPD and GE in free and esterified form plays a key role in ensuring food safety. Proper sample preparation and analysis on a GC-MS device according to the HRN EN ISO 18363-3 standard enables precise quantification of the presence of these contaminants.

The Sample control laboratory applies the HRN EN ISO 18363-3 norm, which provides guidelines for sample preparation and analysis and has a functional method for the analysis of the mentioned contaminants.

_____________

Do you need this service? For more information about the laboratory testing service, feel free to contact us.